![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
STRUX® 90/40 Replaces WWF as Minimum Reinforcing for Composite Steel Floor Deck Construction Technical Bulletin – TB-0003
Composite metal deck is a cost-effective flooring system used in many multi-story buildings. Floors constructed of…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
How DCI® Works – TB-0909
This Technical Bulletin describes the role of corrosion inhibitors, and the way DCI® Corrosion Inhibitor controls…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
Understanding Cracks in Residential Concrete; Control and Prevention
Cracks in concrete come in many sizes and shapes: from superficial but aesthetically displeasing surface cracks,…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
Using ADVA® XT2 – TB-0609
ADVA® XT2 is recommended primarily for use in ready mixed concrete applications where improved slump life…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
A guide to specifying the use of synthetic macro fibers, as an alternative to welded wire mesh, in precast concrete septic tanks – TB-1207
The use of synthetic macro fibers as a replacement for welded wire mesh is becoming wide…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
STRUX® 90/40 Concrete Fibers ASTM C1399 vs. ASTM C1609 – TB-1205
How are fibers tested and evaluated in concrete? There are two ASTM flexural test procedures used…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
DCI® Dosage Rates and ACI Guidelines – TB-0906
Corrosion is an electrochemical reaction similar to the process that takes place inside a battery. In…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
The Effects of DCI® on the Corrosion Rates of Steel in Concrete – TB-0907
A Laboratory Study In 1984 the latest large scale accelerated corrosion test program was initiated examining…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
DCI® What is Corrosion? – TB-0905
This Technical Bulletin 0905 explains chloride induced corrosion of steel in concrete. Steel in Concrete The…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
DCI® Results of FHWA Sponsored Corrosion Studies – TB-0910
This engineering bulletin discusses work done by Wiss, Janney & Elstner Assoc. (WJE) who examined the…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
DCI® Performance in Cracked Concrete – TB-0908
A laboratory study was conducted for three years to test DCI® Corrosion Inhibitor performance in cracked…
![](https://www.chryso.ca/wp-content/uploads/sites/21/2024/11/300x300.jpg)
CONCERA® SA8080 Control Flow – TB-1701
CONCERA® SA8080 is a patented rheology modifying polycarboxylate based ASTM C494 Type A and F high…